Automated Blood Analyzer AM-BAA11 features a sample volume requirement of less than or equal to 9 microliters for whole blood mode and less than or equal to 20 microliters for prediluted mode. This device is equipped with a 10.4-inch TFT touchscreen for easy operation and has high data storage capacity. It supports HL7 protocol via a LAN port for bi-directional LIS communication and includes four USB ports for added connectivity. Its compact and lightweight design make it an ideal solution for precise and reliable hematological diagnostics.
| Sample Volume (Whole Blood Mode) | Less than or equal to 9 μL |
| Sample Volume (Prediluted Mode) | Less than or equal to 20 μL |
| WBC (10⁹/L) Performance |
Linearity Range: 0 to 100 Precision (CV%): Less than or equal to 3.5% (4.0 to 6.9), Less than or equal to 2.0% (7.0 to 15.0) Carryover: Less than or equal to 0.5% |
| RBC (10¹²/L) Performance |
Linearity Range: 0 to 8.00 Precision (CV%): Less than or equal to 2.0% (3.50 to 6.5) Carryover: Less than or equal to 0.5% |
| HGB (g/L) Performance |
Linearity Range: 0 to 280 Precision (CV%): Less than or equal to 1.5% (100 to 180) Carryover: Less than or equal to 0.5% |
| MCV (fL) Performance |
Precision (CV%): Less than or equal to 1.0% (70.0 to 110.0) Carryover: ≤0.5% |
| PLT (10⁹/L) Performance |
Linearity Range: 0 to 1000 Precision (CV%): Less than or equal to 5.0% (100 to 500) Carryover: Less than or equal to 1.0% |
| Hemoglobin Test | Cyanide-Free Reagent |
| Analyzed Parameters | 20 Parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR |
| Throughput | 40 Samples Per Hour |
| Display | 10.4-inch TFT Touch Screen |
| Data Storage Capacity | Up to 100,000 Results |
| Communication Ports | LAN Port (HL7 Protocol, Bi-directional LIS) |
| USB Ports | 4 USB ports |
| Printout | Thermal Recorder, 50 mm Wide Paper, Multiple Printout Formats |
| Operating Temperature | 15°C to 30°C |
| Operating Humidity | 10% to 90% |
| Operating Air Pressure | 70kPa to 106kPa |
| Power Supply | (100V to 240V) ±10%, Less than or equal to 180VA, (50Hz/60Hz) ±1Hz |
| Dimensions (D × W × H) | 410 mm × 300 mm × 400 mm |
| Weight | Less than or equal to 20kg |
Connect with Our Specialists
Abimed Automated Blood Analyzer offer throughput of up to 30 to 70 samples per hour, providing reliable results with minimal carryover. A cyanide-free reagent ensures safe hemoglobin testing, while minimal sample volume of 9 microliters for whole blood makes them ideal for various clinical settings. They measure multiple parameters, including WBC, RBC, HGB, HCT, and PLT, and generate three histograms for detailed analysis. With a lightweight build, these analyzers are space-efficient and highly functional in laboratories and healthcare facilities.