Automated Blood Analyzer AM-BAA10 offers dimensions of 410 mm × 300 mm × 400 mm, designed for precise and efficient blood analysis. It operates in whole blood mode with a sample volume of less than or equal to 9 microliters and prediluted mode with less than or equal to 20 microliters. Its connectivity includes a LAN port and four USB ports, with printouts generated via thermal recorder. This analyzer is designed for reliability, operating efficiently under varying environmental conditions. Additionally, it is ideal for laboratories requiring high-precision, automated blood analysis.
Sample Volume (Whole Blood Mode) | Less than or equal to 9 μL |
Sample Volume (Prediluted Mode) | Less than or equal to 20 μL |
WBC (10⁹/L) Performance |
Linearity Range: 0 to 100 Precision (CV%): Less than or equal to 3.5% (4.0 to 6.9) Carryover: Less than or equal to 0.5% |
RBC (10¹²/L) Performance |
Linearity Range: 0 to 8.00 Precision (CV%): Less than or equal to 2.0% (3.50 to 6.5) Carryover: Less than or equal to 0.5% |
HGB (g/L) Performance |
Linearity Range: 0 to 280 Precision (CV%): Less than or equal to 2.0% (100 to 180) Carryover: Less than or equal to 0.5% |
MCV (fL) Performance |
Precision (CV%): Less than or equal to 1.0% (70.0 to 110.0) Carryover: ≤0.5% |
PLT (10¹²/L) Performance |
Linearity Range: 0 to 1000 Precision (CV%): Less than or equal to 5.0% (100 to 500) Carryover: Less than or equal to 1.0% |
Hemoglobin Test | Cyanide-Free Reagent |
Analyzed Parameters | 20 Parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR |
Throughput | 30 Samples Per Hour |
Display | 8.4-inch TFT Touch Screen |
Data Storage Capacity | Up to 50,000 Results |
Communication Ports | LAN Port (HL7 Protocol, Bi-directional LIS) |
USB Ports | 4 USB ports |
Printout | Thermal Recorder, 50 mm Wide Paper, Multiple Printout Formats |
Operating Temperature | 15°C to 30°C |
Operating Humidity | 10% to 90% |
Operating Air Pressure | 70kPa to 106kPa |
Power Supply | (100V to 240V) ±10%, Less than or equal to 180VA, (50Hz/60Hz) ±1Hz |
Dimensions (D × W × H) | 410 mm × 300 mm × 400 mm |
Weight | Less than or equal to 20kg |
Connect with Our Specialists
Abimed Automated Blood Analyzer offer throughput of up to 30 to 70 samples per hour, providing reliable results with minimal carryover. A cyanide-free reagent ensures safe hemoglobin testing, while minimal sample volume of 9 microliters for whole blood makes them ideal for various clinical settings. They measure multiple parameters, including WBC, RBC, HGB, HCT, and PLT, and generate three histograms for detailed analysis. With a lightweight build, these analyzers are space-efficient and highly functional in laboratories and healthcare facilities.